page_banner

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use – ZhuoRuiHua

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use – ZhuoRuiHua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We persist with the principle of "quality 1st, assistance initially, continual improvement and innovation to meet the customers" for your management and "zero defect, zero complaints" as the standard objective. To great our service, we present the products and solutions while using the very good top quality at the reasonable cost for Rendezvous Procedure Ercp, Disposable Cytology Brush, Injector Needles, Any needs from you'll be paid out with our best notice!
Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use – ZhuoRuiHua Detail:

Application

Disposable sphincterotome is used for endoscopic cannulation of the ductal system and for sphincterotomy.
Model: Triple lumen Outer diameter: 2.4mm Tip length: 3mm/ 5mm/ 15mm Cutting length:20mm/ 25mm/ 30mm Working length:2000mm

Sphincterotome8
Sphincterotome6
Sphincterotome4

The Main Parameters of the Disposable Sphincterotome

1. Diameter
The diameter of the sphincterotome is generally 6Fr, and the apex part is gradually reduced to 4-4.5Fr. The diameter of the sphincterotome needs not much attention, but it can be understood by combining the diameter of the sphincterotome and the working forceps of the endoscope. Can another guide wire be passed while the sphincterotome is placed.
2. The length of the blade
The length of the blade needs to be paid attention to, generally 20-30 mm. The length of the guide wire determines the arc angle of the arc knife and the length of the force during incision. Therefore, the longer the knife wire, the closer the “angle” of the arc is to the anatomical direction of the pancreaticobiliary duct intubation, which may be easier to intubate successfully. At the same time, too long knife wires may cause miscutting of the sphincter and surrounding structures, resulting in serious complications such as perforation, so there is a “smart knife” that meets the needs of safety while meeting the length.
3. Sphincterotome identification
The identification of the sphincterotome is a very important piece, mainly to facilitate the operator to easily understand and identify the position of the sphincterotome during the subtle and important incision operation, and to indicate the common position and safe incision position. Generally speaking, several positions such as “start”, “start”, “midpoint” and “1/4″ of the sphincterotome will be marked, of which the first 1/4 and the midpoint of the smart knife are relatively safe positions for cutting , more commonly used. In addition, the midpoint marker of the sphincterotome is radiopaque. Under the X-ray monitoring, the relative position of the sphincterotome in the sphincter can be well understood. In this way, combined with the length of the exposed knife under direct vision, it is possible to know whether the knife can safely perform sphincter incision. However, each company has different logo habits in the production of logos, which needs to be understood.

Sphincterotome5


Product detail pictures:

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use  – ZhuoRuiHua detail pictures

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use  – ZhuoRuiHua detail pictures

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use  – ZhuoRuiHua detail pictures

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use  – ZhuoRuiHua detail pictures

Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use  – ZhuoRuiHua detail pictures


Related Product Guide:

We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance for Good Quality Guidewire - ERCP Instruments Triple Lumen Single Use Sphincterotome for Endoscopic Use – ZhuoRuiHua , The product will supply to all over the world, such as: Milan, Italy, Zurich, With strong technical strength and advanced production equipment, and SMS people purposefully , qualified, dedicated spirit of enterprise. Enterprises took the lead through the ISO 9001:2008 international quality management system certification, CE certification EU ; CCC.SGS.CQC other related product certification. We look forward to reactivating our company connection.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Hannah from Mongolia - 2018.09.12 17:18
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Joa from Nigeria - 2018.09.19 18:37